| Measuring Method | Dual Slope A/D Conversion |
| Sampling Rate | 2.5 Samples per Second |
| Display Type | Red LED Super Bright Display |
| Maximum Display | 19999 Counts |
| Resolution | 0.0001 to 1 Count depending on the range |
| Polarity Indication | “ - ” is indicated for negative input |
| Decimal Selection | Field Selectable |
| Over Range Indication | "0000" blinking |
| Maximum Overload | Voltage : 1.2 times continuous Current : 2 times continuous |
| VA Burden (Typical) | Auxiliary (110 / 230V AC) : < 5VA Auxiliary (SMPS) : < 2.5VA Voltage Input : < 0.1VA Current Input : < 0.5VA, < 0.2VA in 20A |
| Frequency Response | 40 - 400Hz |
| Crest Factor | 4 (max.) TRMS accuracy specified for sine wave input |
| Faceplate / Lens | Red Antiglare Faceplate with Annunciators |
| Environment | Calibration : 27OC ± 5OC, Operating : 0 to 50OC, RH < 70% Storage : -10 to 60OC, RH < 70% |
| Dielectric Strength | 2.5 kV at 50Hz for 1 min. between Input - Auxiliary - Case - Terminals |
| Case / Housing Material | DIN Black ABS, Dimension as per DIN 43700 |
| Mounting Clamps | Sturdy, Moulded ABS with suitable Hardware |
| Connectors | Terminal Block : Thermoplastic (UL 94V-0) with Tin Plated Brass Terminals |
| Display Stability | Within ± 2 Digits |